Dew Point Meters, Hygrometers, Moisture Analyzers and Dew Point Meter Accessories. At Shaw Moisture Meters we believe choosing the correct dew point measurement products for your application is essential. Therefore, an important part of our service is to ensure you receive the right dew point device for your application, every time.
[email protected]Notice Our Odessa office has moved. The new location is at 8007 East Business 20, Odessa, TX 79765. Contact us at +1 432 272 1180.
Get PriceHydrocarbon Dew Point Installation The NGC8206 is a weatherproof device designed for installation “on the pipe” near to the sampling point. This means it is acceptable to mount outside - in a temperature range of 0&F to 130&F (–18&C to 55&C) [provides reliable
Get Pricetreatment. Excessive dust content, temperature and dew point as well as excessively high or low pressure and, last but not least, interfering components in the sample gas can impair the operability of the gas analyzer and falsify the measurement result. • System components such as
Get Priceadded to a blend, the Hydrocarbon Dew Point (HDP) of that blend will tend to make it become a liquid unless kept and sampled at a high temperature. Greater than 1000 ppm of C6, C7, C8, or C9 increases the HDP to such a point the mixture would have to be heated beyond 120F
Get PriceFor the fan control the devices features an analog output for the control of a continues fan. A relay output switches an additional load of up to 16 A, such as auxiliary heating. Over 4 inputs the room status can be detected and monitored (Use for window contact, dew point sensor, level sensor or temperature sensor).
Get PriceThe dew point of the sample gas must be at least 5 &C lower than the lowest ambient temperature in the overall sample gas path. Otherwise, a sample gas cooler or condensate trap is required. Positive pressure 2...500 hPa Flow 20...100 l/h Flammable Gases The analyzer version with stainless steel gas lines and gas connections is suitable
Get PriceTemperature The dew point of the sample gas must be at least 5 &C lower than the lowest ambient temperature in the overall sample gas path. Page 22 EL3000 CONTINUOUS GAS ANALYZERS CI/EL3000-EN REV. B Dew point The dew point of the test gases must be approximately the same as the dew point of the sample gas.
Get PriceStandard interfaces are 4…20mA, Modbus RTU or M-Bus. Furthermore, all dew point sensors can be combined easily with our data loggers. Dew point sensors form CS Instruments enables a reliable and long-term stable monitoring of the pressure dew point in industrial applications from -80 to +20 &C dew point. We recommend the indirect installation with measuring chamber.
Get PriceThe high temperature tolerance of the sensor allows direct measurement from hot process without the need for a sampling system and sample conditioning. The wide dynamic rage of the measurement in DMT345 and DMT346 is unique: Measurements can be made from -40 &C frost point up to +100 &C dew point, with dry-bulb temperatures ranging up to 350 &C.
Get PriceHandheld Dewpoint Meter DM70 for spot-checking applications and field calibration offers accurate and fast measurement for industrial dew point applications, such as compressed air, metal treatment, additive manufacturing as well as food and plastics drying. DM70 measures dew point temperature accurately over a wide measurement range.
Get PriceGulf Coast TMC integrates the ABB Gas Chromatograph into a skid mounted platform consisting of an ABB C6+ or C9+ Gas Chromatograph mounted, tubed, wired and terminated in an ABB Cold Weather Enclosure. The Cold Weather Enclosure is heated electrically via an Intertec Varitherm 400W Fin Heater or a Natural Gas Bruest Heater.
Get PriceAlternatively the Fan Coil Controller ca be used as Actuator for a KNX Room Thermostat. The two binary inputs for 24 V AC signals can be used for example to connect a window sensor or a dew point sensor. The device has a build in power supply for the 24V AC Sensors. The
Get PriceABB i-bus. Two binary inputs are available, for example, as signalling contacts for window contact and dew point monitoring. The scanning voltage for the binary inputs is provided by the device. The actuator is a modular installation device with a module width of 4 space units in Pro M design for in-stallation in the distribution board.
Get PriceThe NGC8209 provides precise and reliable measurement of an extensive range of natural gas values, from C 6 + to C 9 +. This range includes hydrocarbon dew point, a complex and traditionally difficult-to-measure parameter.
Get PriceThe device has 4 channels each for the independent control of a heating or cooling application. Each channel has an electronic valve output for the control of a thermoelectric valve drive, as well as 3 inputs to detect and monitor the room status (use for window contact, dew point sensor, level sensor or temperature sensor).
Get PriceBinary input – e.g. for window contact, dew point sensor, fill level sensor – One or alternating two values can be sent (1 bit, 1 byte, Scene number, RTC operating mode) Analogue input for external temperature sensor PT1000 / DP4-T-1 – e.g. for additional or external temperature sensor or ceiling/ floor temperature measurement – PT1000 or DP4-T-1 sensor (ABB) – Line fault compensation via cable resistance or
Get PricePage 33 ABB i-bus EIB / KNX Project design and programming 24 Dew point detector – Dew point signal (EIS 1: 1 Bit) The Fan Coil Controller receives a dew point alarm via this communication object and deactivates the cooling mode. The cooling mode is reactiva-
Get PriceMeasures humidity, temperature and dew point. This measuring device calculates all the psychrometric parameters in the fields of pharmaceuticals, food, HVAC and across Industry. One outstanding feature of this measurement device is the possibility to output any
Get PriceScene support for virtual devices. As all devices in [email protected] smart home system the virtual devices created by calling the virtualdevice endpoint can be configured and used with scenes. This means the enduser is able to trigger a scene (using the frontend, a switch,) and the SysAP will inform all configured devices for the scene to switch to a specified state.
Get PriceFor the examples to work, you need to connect to your System Access Point 2.0 in access point mode. To activate the Access Point mode, press the button on the System Access Point. A blue LED light signals the access point mode. Alternatively, you can change the url in the following examples to match the IP-address of your local System Access Point.
Get Pricesensors with a new surface mounted device – Existing range: • 6109/28 with display • LGS/A 1.1 with colored LED – New: • Air quality sensor LGS/A 1.2 • CO 2 Measurement and control • Measurement of relative humidity and control • Temperature measurement and control • Air pressure measurement • Dew point calculation
Get PriceDew Point Meters, Hygrometers, Moisture Analyzers and Dew Point Meter Accessories. At Shaw Moisture Meters we believe choosing the correct dew point measurement products for your application is essential. Therefore, an important part of our service is to ensure you receive the right dew point device for your application, every time.
Get PriceDew point is a calculated value, based on temperature and humidity. At low negative dew point temperatures, the calculation is highly dependent on relative humidity and changes of ±3% RH (the tolerance of the PosiTector DPM’s humidity sensor) can have a significant impact on the dew point
Get PriceEMT Americas-EMT, dba EMT UK Ltd, has released the AsserolyzIR- multi-gas SF6 Asset management analyzer.This is an accurate and repeatable field analyzer for SF6, using new, patented NIDR technology to measure SF6 purity, CF4, HF, dewpoint and SO2(electrochemical).
Get PriceWe are the manufacturer of Handheld Digital Dew Point Meter with range of -80 to + 30 Deg C in India Dew Point Indicator Applied portable handheld battery operated Dew Point Meter model ATS-301D are designed to measures dew point, Moisture and temperature faster and accurately over a wide measurements range .Model ATS-301D is highly optimized to measure the dew point, moisture and
Get PriceApr 07, 2016The chilled beams in this example require 55 degree air (the supply air dry bulb set point, SASP) with a maximum dew point of 48 degrees (the supply air dew point set point, SADP). In the typical DOAS system, the chilled water coil will cool the air down to the SADP (48 degrees) to remove the necessary moisture.
Get PriceHoneywells early-warning dew point sensor is designed for use in monitoring cooling water pipes or chilled surfaces in order to determine if temperatures are approaching the dew point. The device enables local controller configuration through an easy to use touch screen interface with menu driven selections. T7xxx Series.
Get PriceExtech EN510. 10-in-1 Environmental Meter Measures Air Velocity, Air Flow, Air Temperature, Type K Temperature, Heat Index, Humidity, Wet Bulb, Dew Point, Windchill, and Light Level
Office Add: Kexue Revenue, High and New Technology Industrial Development Zone, Zhengzhou, China