Now offering dew point calibration in a wide range from a few PPM towards the boiling point of water. Dew point calibration services include. ISO/IEC 17025 accredited calibrations from -60 to +95&C (-76 to +203&F) dew point; Schedule of Accreditation

[email protected]

News Detail

  • Instrument Air Quality Dew point Dry Air Quality

    The pressure dew point as measured at the dew point outlet shall be at least 15-20 deg C below the minimum ambient/ surroundingtemperature to which any part of the instrument air system is exposed. also the pressure dew point shall not exceed +2 deg C line pressure i.e. (-) 23 deg C at atm pressure,

    Get Price
  • DEW POINT IN COMPRESSED AIR Dew Point in Compressed

    Dew point temperature is a measure of how much water vapor there is in a gas. compressed air may have specific dryness specifications. Finally, medical and pharmaceutical processes may treat below. As an example, a system that conforms to ISO8573.1 and is rated for class 1.1.1 will provide air with a dew point

    Get Price
  • Model GCTU-CMH-PTY-SO2 - Dewpoint

    •Pre-set alarm points to IEC 60480:2004 for dew-point, % and ppmv for both MV and HV installaions. •Integrated Chilled Mirror Dewpoint Hygrometer, SF6purity and SO 2analyser. •Unlimited Fill/Discharge Cycles. •Dual voltage 240v or 110 opion available. •12 bar (175 PSIG) maximum back fill pressure.

    Get Price
  • Dew Point Calibration | UK Calibration Laboratory

    Now offering dew point calibration in a wide range from a few PPM towards the boiling point of water. Dew point calibration services include. ISO/IEC 17025 accredited calibrations from -60 to +95&C (-76 to +203&F) dew point; Schedule of Accreditation

    Get Price
  • PRACTICAL HYDROCARBON DEW POINT SPECIFICATION FOR

    measured droplet dew point in Figure 5. The SRK calculated dew point given in RR-196 agrees slightly better with the manual droplet dew point than does the Ametek automated dew point which was tuned to the iridescent ring. As previously stated, the iridescent ring method should give higher dew point values than the droplet method.

    Get Price
  • Air Quality Standards ISO 8573.1 ISO12500 | Compressed

    Dew point, specified as temperature, is the point at which the water vapor held in the compressed air is equal to the compressed air’s capacity to hold water vapor. Desiccant dryers- using activated alumina- will adsorb water vapor from the air most effectively, delivering ISO 8573.1 Quality Class 2 (-40( F/-40( C) pressure dew point), ideal for the food processing industry. At this level of dryness,

    Get Price
  • Analysing the transport phenomena of novel dew-point

    Generally, the most common IECs configurations can be classified into two categories, namely, conventional IEC and regenerative IEC as shown in Figs. 1(a) and (b). The regenerative IEC is also referred to as the dew-point evaporative cooler (DPEC)

    Get Price
  • Data Center Temperature and Humidity Requirements

    Maximum dew point: 15&C (59&F) Maximum rate of temperature change: 5&C (9&F) per hour; The upper limits have been specified to for relative humidity and dew for the purpose of reducing failures caused by conductive anodic filament growth on printed circuit board laminate materials. The upper limits have changed from 25 to 27 C (77 to 81 F) .

    Get Price
  • TECHNICAL SPECIFICATIONS OF INSULATING OIL TESTING SET

    System Characteristics Voltage Level 1. Normal System Voltage, kV 230 132 33 11 3. Maximum System Voltage, kV 245 145 36 12 4. System Frequency, Hz 50 50 50 50 5. Phase Rotation (Anti-Clock wise) RST RST RST RST 6. Type of System Grounding Solid Solid Solid Solid 7. Rated Fault Level (3-Phase Symmetrical), MVA 3 sec.

    Get Price
  • Dew Point Sensors, Meters and Monitors Measure Monitor

    The Dew Point is the lowest temperature that allows water vapour to remain in a gas without condensing to a liquid state. As the air or gas temperature drops, its ability to absorb water vapour drops until it becomes completely saturated and below this dew point temperature, water droplets will

    Get Price
  • SF6 Gas Analysis - Qrometric

    For SF6 filled gas compartments, SF6 in accordance with either IEC 60376 or IEC 60480 is used. In order to prevent condensation, the maximum allowable water content is defined by a dew-point no higher than – 5 &C. Gas compartment fill specifications typically define much lower dew points (manufacturer dependent).

    Get Price
  • Dew Point Evaporative Comfort Cooling

    Dew Point Evaporative Comfort Cooling . Energy and Water Projects . Demonstration Plan SI-0821 . TP-7A40-56256-1 . November 2012 . Jesse Dean, Lesley Herrmann, Eric Kozubal, and Jesse Geiger (National Renewable Energy Laboratory) Mark Eastment (Eastment Consulting Inc.) Steve Slayzak (Coolerado) Link to Summary Report

    Get Price
  • ISO/IEC 17025 Accredited Calibration Laboratory

    ±1.0% RH at a dry bulb temperature between 20&C and 30&C and a dew point range of -6&C to 23&C Calibration over the entire range from 12% to 85% RH 12% to 85% RH

    Get Price
  • HUMICAP Humidity and Temperature Transmitters HMT120

    Mechanical Specifications. IP rating IP65 Weight 270 g (9.5 oz) Probe cable lengths 3 m, 5 m, 10 m - up to 50 m (9.8 ft, 16 ft, 33 ft - up to 164 ft) Display (optional) 128 x 64 resolution full graphics BW display without backlight. Material.

    Get Price
  • Transmitter, models GDT-20, GDHT-20 EN

    these, the transmitter calculates the values gas density and dew point/frost point (only model GDHT-20) information of the SF6 gas in order to evaluate the state of the system. All stated parameters can be read from the Modbus protocol via the RS-485 interface. The model

    Get Price
  • Transmitter for Moisture Analysis - Michell Easidew PRO I.S.

    Performance Specifications: Measurement Range -110 to +20&C (-166 to +68&F) dew point; -100 to +20&C (-148 to +68&F) dew point: 0 to 1000 ppm W capability – factory configured to customer-required range and application: Accuracy ±1&C (±1.8&F) dew point (+20 to -60&C / +68 to -76&F) ±2&C (±3.6&F) dew point (-60 to -110&C / -76 to -166&F)

    Get Price
  • Dew Point Calibration Services in Los Angeles | MQC

    Dew Point Calibration Services in Los Angeles A Calibration Lab That Services Customers’ Precision Measurement Equipment Nationwide. Opposed to the “calculated” dew point readings that customers can derive from certain temperature/humidity instruments, Micro Quality Calibration (MQC) boasts our accredited capability and technical proficiency in providing our customers with a calibrated

    Get Price
  • Questions Misconceptions about GIS SF6 Gas Systems

    Feb 01, 2012(droplets or dew) or solid (ice). Typical dewpoint in SF6 equipment ranges from -60C to -5C. Common operating pressures are 100-755 kPa abs. (0-95 psig). ppmv: Moisture Volume concentration (parts per million by 15 1/18/2012 Volume). One million times the ratio of the volume of moisture (water vapor) present in the gas to the total volume of the gas

    Get Price
  • WP4C | Soil Water Potential in the Lab | METER Environment

    At the dew point, the WP4C measures both mirror and sample temperature within 0.001 &C. This allows for unparalleled accuracy in the -0.1 MPa to -300 MPa range so you can have full confidence in sample readings. Measuring soil water potential has never been simple

    Get Price
  • Precision Compressed Air Chilled Mirror Dew Point Hygrometer

    ISO/IEC 17025:2005 Accredited ISO 9001:2008 Certified A Robust, High Accuracy Dew Point Hygrometer for Monitoring and Controlling Compressed Air Systems The COM.AIR dew/frost point monitor has been designed to offer the highest level of reliability and accuracy available in compressed air systems dew/frost point measurement.

    Get Price
  • Technical Specifications - Metasys - LIT-12012320

    Storage: -40 to 70&C (-40 to 158&F); 5 to 95% RH 30&C (86&F) maximum dew point conditions Operating: 0 to 50&C (32 to 122&F); 5 to 95% RH, 30&C (86&F) maximum dew point conditions. Transmission Power (Wi-Fi) (Typical) Wireless Local Area Network (WLAN) Transmission Power: +14.5 dBm, 54 Mbps +12.5 dBm, 65 Mbps. WLAN Receiver. Sensitivity (Typical)

    Get Price
  • Refrigerated Type Dryer - Manufacturer,Supplier,Exporter

    To prevent freezing of condensed moisture in the heat exchanger, Air/Gas, can be cooled to a minimum temperature of +2-30C approx i.e. the dew point of dried fluid at operating pressure 7 kgf/Cm2g is (+) 20C and its corresponding atmospheric dew point would be (-) 220C (approx).

    Get Price
  • Condensation Control Calculator for Horizontal Pipe | WBDG

    (The thickness that provides average surface temperature Dew Point + a safety factor of 0.75&F) NA = Not Available. Some sizes and thicknesses may not be commercially available and some materials are available in sizes and thicknesses not listed. Assumptions. One dimensional, steady state heat transfer; Base structure is a horizontal steel pipe

    Get Price
  • BACnet Router Technical Specifications - BCPro - LIT

    0&C to 50&C (32&F to 122&F); 10% to 90% RH, 30&C (86&F) maximum dew point. Ambient Storage Conditions-40&C to 70&C (-40&F to 158&F); 5% to 95% RH, 30&C (86&F) maximum dew point. Data Protection Battery: Supports data protection on power failure.

    Get Price
  • Heated Dew/Frost Point Hygrometer System

    ISO/IEC 17025:2005 Accredited ISO 9001:2015 Registered The Edgetech Instruments Inc DPS Series consists of heated, primary method, chilled mirror hygrometer systems that continuously measure the dew/frost point of high dew point gases from high temperature environments. When the dew/frost point temperature of a sampled gas is

    Get Price
  • The SF6-ReUse-Process A contribution on the sustainability

    Dew point or frost point measuring devices are used to determine the moisture concentration. The devices automatically display the dew point or frost point in ppm H. 2. O or in degree centigrade. If the gas contains contaminants caused by decomposition, SO. 2 . is formed as a stable end product.

    Get Price
  • Meteorological Humidity System - Instrumart

    dew/frost point temperature and is measured by an embedded precision platinum resistance thermometer. Below 0&C, the system tracks the frost point. All Edgetech Instruments dew/frost point hygrometers are manufactured and supported in the USA in a modern, ISO 9001:2008 registered facility with ISO/IEC 17025:2005 accredited calibration

    Get Price
  • Moisture Analyzers and Hydrocarbon Dew Point Analyzers

    Hydrocarbon dew point (HCDP) and moisture are key quality parameters to ensure the quality of pipeline transmission gas. With the combined Condumax II and OptiPEAK TDL600 analyzer system pipeline operators have the assurance of the most widely accepted automatic hydrocarbon dew point analyzer together with the latest development of spectroscopic moisture measurement techniques in a single

    Get Price
  • Power Generator Hydrogen Monitoring and Optimization

    SYSTEM FUNCTIONS Continuous Monitoring Hydrogen Purity (H 2 in Air) and Dew Point Measurement and Control Hydrogen Purity and Dew Point while maintaining specified pressure Re-Gas Monitoring H 2 in Air, H 2 in CO 2, Air in CO 2 SYSTEM REQUIREMENTS Electrical Specification 110 to 240 VAC, single phase, 5 amps, 50 or 60 Hz Inlet H 2